Skip to content

+J8000

– Hidden Sheet European Thermal Break Chamber 70mm –

Performance
Thermal Transmission Coefficient Uw

1.26 W/m²K

Acoustic Attenuation Coefficient

42dB (-1, -4)

Energy Class

Class A

Air Permeability (EN 1026)

Class 4

Watertightness (EN 1027)

Class E900

Wind resistance (EN 12211)

Class C5

Minimum rim width

75 mm

Minimum Rim View

60 mm

Minimum view Rim + Leaf

70 mm

Maximum Height

3000 mm

Maximum Length

1700 mm

Maximum Weight

160 kg

Bit height

20 mm

Glass filling

55 mm

Thermal break

24 mm

League

6060

General thickness

1.7 mm

Types of opening

Opening window 1 vent
Interior opening
Opening window 2 vent
Interior opening